Cross-Hatch Adhesion Test: What a Faucet Finish Report Measures

Review the coating, substrate, method and reported adhesion rating together. Keep adhesion separate from hardness, scratch resistance and service life.

A coated flat test coupon with a small cross-cut grid, tape and an inspection magnifier.
On this page

    A cross-hatch adhesion test assesses a coating's response to a specified cut-and-tape test. The result is a visual classification of coating removal, not an absolute bond-force measurement, a scratch-proof claim or a prediction of faucet service life. Read the rating together with the method, tested coating and substrate.

    For a buyer reviewing faucet finishes, the first question is whether the method is suitable for the proposed finish system. The second is whether the identified sample represents the model and finish being ordered. A rating without that information is an incomplete submittal.

    What ASTM D3359 Covers

    The public scope of ASTM D3359-23 describes tape-test methods for relatively ductile coating films on metallic substrates. It includes different methods and defined limitations. The method should be selected for the coating and its thickness rather than applied indiscriminately to every surface finish.

    A faucet described as plated, PVD-coated, lacquered or painted does not automatically qualify for one identical test. Ask the laboratory or finish specialist to establish method suitability for the actual coating system and substrate. A report about a paint film cannot automatically validate a different surface treatment.

    The public guidance also distinguishes this classification from measuring an absolute adhesion force and from resolving fine differences between strong bonds. Keep those limitations with the result when it enters a product specification.

    Read the Rating With Its Method

    ASTM Method B reports commonly use a classification such as 5B. The testing-equipment manufacturer's Elcometer classification explanation illustrates 5B as no lattice coating detached, with progressively lower classifications for greater removal. That describes the observed test area under the specified conditions.

    It does not mean that a faucet is universally scratch-proof or that every visible surface has been evaluated. It also does not establish a mandatory acceptance grade for SANIKB products. The applicable purchase or product requirement determines which result is acceptable.

    Item on the report

    How to read it

    A classification such as 5B

    Read the visual result under the named method, not as a force value or years of durability.

    A photograph of the assessed area

    Check that it is connected to the sample identifier and stated result.

    “Pass”

    Find the acceptance rule and the configuration to which it applies.

    A result under another standard

    Retain its own method and scale; do not substitute an ASTM label.

    ASTM and ISO Results Are Not Interchangeable

    ASTM D3359 and ISO 2409 address related cross-cut coating assessments, but their methods and classifications should not be treated as technically equivalent. Elcometer's published explanation illustrates opposite rating directions: the favorable ASTM endpoint is 5B, while the favorable ISO endpoint is class 0.

    That contrast is a warning against reading a bare number. It is not a conversion table authorizing one report to replace the other. Retain the standard, edition and method with the result, and ask the reviewer to assess whether it meets the specified requirement.

    If two suppliers submit different methods, record that difference before comparing their ratings. “Five” does not always mean the same outcome, and a shared description such as “cross-hatch tested” is not enough to resolve the method.

    Adhesion vs Pencil Hardness and Scratch Resistance

    Adhesion concerns whether the coating remains attached under the chosen adhesion test. A pencil hardness test addresses a different coating property through its own method. Scratch and abrasion assessments likewise require their own definitions and evidence.

    A report may list several results, but they are not interchangeable or additive scores. A favorable adhesion classification does not answer how a surface responds to every cleaning product, repeated rubbing, a sharp object or an installation tool.

    Keep each claim connected to the test that supports it. If a brochure calls a finish “scratch resistant” but supplies only an adhesion rating, ask for clarification rather than interpreting the rating as evidence of the separate claim.

    Identify the Coating, Substrate and Sample

    Finish color alone does not describe the tested coating. Ask for the model and finish designation, substrate and coating-system information that identifies the sample. If a result is offered for several finishes, request the basis for that coverage.

    A flat test panel and a finished faucet component are different specimens. Either may be useful for a defined purpose, but the report should explain what was evaluated and how that sample relates to the proposed supply. Do not assume a panel result establishes performance at every part of a completed faucet.

    For multilayer systems, ask what the reported removal means. Did the observed separation concern the surface layer, an interface within the coating system or another boundary? The reviewer may need more information than the final classification alone.

    Submittal question

    Information to retain

    Which product does this cover?

    Model, finish and sample or batch identification

    What was tested?

    Substrate, coating system, thickness information and specimen form

    Which method was used?

    Standard, edition, method and reported deviations

    How was the result evaluated?

    Classification, sample-linked photographs and the acceptance requirement

    How does it represent this order?

    The connection between the test specimen and proposed configuration

    Compare Reports on a Common Basis

    Begin with sample identity and method suitability. Then compare the coating system, substrate, specimen preparation, documented test materials and evaluation rule. Where those differ, clarify the difference instead of automatically choosing the larger rating.

    Testing involves operator and method conditions, so a classification should not be read as unlimited measurement precision. A small difference between reports does not automatically establish a meaningful product advantage. Ask the laboratory or specification reviewer whether the comparison is supported.

    The outcome of the review may be a request for missing information, a report aligned with the agreed method or a documented acceptance decision. The outcome should identify the specific configuration covered rather than create a blanket approval of all finishes from that supplier.

    Use the Evidence in a Finish Selection

    For an order or project, keep the approved finish designation and test evidence with the purchase record. Ask how later changes in the substrate, coating system or supplied configuration affect the applicability of the report. Testing frequency and batch coverage should come from the agreed quality plan, not an assumed universal factory routine.

    Appearance and assortment decisions remain separate. The faucet finishes guide and finish color guide address those choices. Neither replaces model-specific test evidence or the exact care instructions.

    For SANIKB quotations, identify the required model and finish and ask which relevant documentation is available. Do not infer a particular rating, certification or acceptance threshold before the supporting record is supplied.

    Frequently Asked Questions

    Does a 5B result mean a faucet is scratch-proof?

    No. It describes coating removal under the named adhesion-test conditions. Scratch resistance and other finish properties require separate evidence.

    Can a homeowner perform a cross-hatch test on an installed faucet?

    Do not cut or tape-test the installed finish as an informal acceptance check. The test alters the coating and needs an appropriate specimen, method and evaluation. Ask for the existing report or a suitable professional assessment.

    Can an ISO class 0 be rewritten as ASTM 5B?

    No. Although they are favorable endpoints in the respective classification explanations, the methods are not interchangeable. Preserve the actual standard and result.

    Is the same test suitable for every plated or PVD finish?

    Method suitability depends on the coating and substrate. Ask the laboratory or finish specialist to establish that scope for the specific system.

    What is missing from a brochure that says only “adhesion passed”?

    The method, tested sample and acceptance rule. Request the complete report and its relationship to the offered model and finish before using the statement as purchase evidence.